Biochemistry Analyser By Horiba

Description

Pentra C200

HORIBA Medical Clinical Chemistry Analysis Pentra C200

Reliabilty and accuracy

Overview

  • Fixed cycles provide continuous throughput of 90 colourimetric tests/hour
  • Optional high throughput ISE module (270 tests/hour)
  • Reagent management with unique “Pentra” cassette
  • Fully automatic cuvette management – 2 racks of 96 single use cuvettes
  • Dedicated waste compartment for used cuvettes and contaminated liquid
  • Integrated computer and cooling unit (Peltier)

 

Product Description

  • Analysis Method Types:
    • Spectrophotometry: Colorimetry and Turbidimetry
    • Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
  • 15 parameters per reagent tray
  • Optional ISE Module (Na+, K+, Cl-)
  • Maximum Throughput: up to 360 test/h (140 tests/h in standard configuration)
  • CE Marked

Sample Handling

  • Sample Capacity: 15 positions in refrigerated compartment
  • Dedicated stat position in Random access
  • Positive Sample Identification: Integrated Barcode Reader
  • Sampling Needle: Level, and Shock Detection
  • Sample Collection Format: 2, 3, 4, 5, 7 and 10 mL (diameter: from 13 to 6mm)
  • Sample Specimen: Serum, Plasma, Urine, CSF, Homogeneous Fluids
  • Sample Volume: 2 to 45 µL (0.1 µl increment)
  • Automatic Sample Dilution: from 1/2 to 1/30,625
  • ISE: 20 µL (Indirect) or 93 µL (Direct)
  • Automatic Post Concentration: from x2.0 to x 20.0
  • Automatic Re-run

Calibrator/Control Handling

  • Calibrator/Controls Positioning on Sample Tray in the Refrigerated compartment
  • Automatic Standard Dilution Series:
    • Dilution Factors: Main Direct 1/2 – 1/175
    • Dilution Factors: Main Indirect 1/176 – 1/30 6258

Reagent Handling

  • 15 parameters on board in a closed refrigerated area (8-15°C)
  • Positive Reagent Identification: Integrated Barcode Reader
  • Reagent Needle: Level Detection and shock detection
  • Reagent management with cassettes: Automated Reagent On-board Stability Check plus continuous test countdown check by capacitive effect.
  • Reagent Volume: from 20 to 350 µL

Reaction System

  • Reaction Volume: 120 to 450 µL
  • Reaction Temperature: Air bath at 37°C
  • Photometer Reaction Cycle:20 seconds
  • Homogenization with Stirring Paddle
  • Reaction Time: 1 to 29 cycles
  • Disposable Acrylic Cuvettes
  • Automatic Cuvette Changer
  • Cuvette Capacity: 192 cuvettes (2 racks of 96 cuvettes)
  • 7 Integrated Calculation Algorithms

 

Pentra C400 Video (click here)

 