Biochemistry Analyser By Horiba

Description

Pentra C200

HORIBA Medical Clinical Chemistry Analysis Pentra C200

Reliabilty and accuracy

Overview

  • Fixed cycles provide continuous throughput of 90 colourimetric tests/hour
  • Optional high throughput ISE module (270 tests/hour)
  • Reagent management with unique “Pentra” cassette
  • Fully automatic cuvette management – 2 racks of 96 single use cuvettes
  • Dedicated waste compartment for used cuvettes and contaminated liquid
  • Integrated computer and cooling unit (Peltier)

 

Product Description

  • Analysis Method Types:
    • Spectrophotometry: Colorimetry and Turbidimetry
    • Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
  • 15 parameters per reagent tray
  • Optional ISE Module (Na+, K+, Cl-)
  • Maximum Throughput: up to 360 test/h (140 tests/h in standard configuration)
  • CE Marked

Sample Handling

  • Sample Capacity: 15 positions in refrigerated compartment
  • Dedicated stat position in Random access
  • Positive Sample Identification: Integrated Barcode Reader
  • Sampling Needle: Level, and Shock Detection
  • Sample Collection Format: 2, 3, 4, 5, 7 and 10 mL (diameter: from 13 to 6mm)
  • Sample Specimen: Serum, Plasma, Urine, CSF, Homogeneous Fluids
  • Sample Volume: 2 to 45 µL (0.1 µl increment)
  • Automatic Sample Dilution: from 1/2 to 1/30,625
  • ISE: 20 µL (Indirect) or 93 µL (Direct)
  • Automatic Post Concentration: from x2.0 to x 20.0
  • Automatic Re-run

Calibrator/Control Handling

  • Calibrator/Controls Positioning on Sample Tray in the Refrigerated compartment
  • Automatic Standard Dilution Series:
    • Dilution Factors: Main Direct 1/2 – 1/175
    • Dilution Factors: Main Indirect 1/176 – 1/30 6258

Reagent Handling

  • 15 parameters on board in a closed refrigerated area (8-15°C)
  • Positive Reagent Identification: Integrated Barcode Reader
  • Reagent Needle: Level Detection and shock detection
  • Reagent management with cassettes: Automated Reagent On-board Stability Check plus continuous test countdown check by capacitive effect.
  • Reagent Volume: from 20 to 350 µL

Reaction System

  • Reaction Volume: 120 to 450 µL
  • Reaction Temperature: Air bath at 37°C
  • Photometer Reaction Cycle:20 seconds
  • Homogenization with Stirring Paddle
  • Reaction Time: 1 to 29 cycles
  • Disposable Acrylic Cuvettes
  • Automatic Cuvette Changer
  • Cuvette Capacity: 192 cuvettes (2 racks of 96 cuvettes)
  • 7 Integrated Calculation Algorithms

 

Pentra C400 Video (click here)

 

Reviews

There are no reviews yet.

Be the first to review “Biochemistry Analyser By Horiba”

Your email address will not be published. Required fields are marked *

X
Exit mobile version